Ionizer   IZS31

Series/CADIon generation methodIon balance
IZS31 Corona discharge type±30 V or less
(±100 V in the case of stainless
steel electrode needle)
Features
  • Discharge time: 0.3 sec.
  • The choice of 2 types of the sensors are available.
    • E High-speed discharge using feedback sensor
    • E Ion balance control by an autobalance sensor

Electrostatic Sensor   IZD10/IZE11

Series/CADMeasurement potentialOutput voltageEffective
detection distance
IZD10-110 ±0.4 kV
(At detection distance 25 mm)
1 to 5 V
(Output impedance:
Approx. 100 Ω)
10 to 50 mm
IZD10-510 ±20 kV
(At detection distance 50 mm)
25 to 75 mm

SeriesRated measurement rangeMinimum unit settingOutput
IZE11 -0.4 kV to +0.4 kV
-20 kV to +20 kV
0.001 kV
(at ±0.4 kV)
0.1 kV
(at ±20 kV)
Switch output x 2 + Analog output
(1 to 5 V, 4 to 20 mA)
Features
  • Detects electrostatic potential of the workpiece, and is capable of switch output, analog output or output of current.

Handheld Electrostatic Meter   IZH10

Series/CADRated charge amount rangeMinimum display unit
IZH10 ±20.0 kV0.1 kV (±1.0 to ±20.0 kV)
0.01 kV (0 to ±0.99 kV)
Features
  • Easy-to-use handheld electrostatic meter

     Ionizer/Fan Type IZF10

・Compact design: 80 mm x 110 mm x 39 mm
・Weight: 280 g
・Static electricity elimination time: 1.5 seconds
・With alarm function
 High-voltage error, electrode needle contamination detector